{"id":9076,"date":"2019-12-12T09:11:39","date_gmt":"2019-12-12T09:11:39","guid":{"rendered":"http:\/\/thermacote.eu\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/"},"modified":"2019-12-12T09:11:39","modified_gmt":"2019-12-12T09:11:39","slug":"lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung","status":"publish","type":"case-study","link":"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/","title":{"rendered":"Lyeffion Elementary School Energienutzungstest mit ThermaCote Keramikbeschichtung"},"template":"","application-type":[],"_edit_last":"","_edit_lock":"","_elementor_controls_usage":[],"wpcf-main-image":"http:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/Evergreen-School-3rd-Party-Report-30-percent-kWh-reduction_page5_image1_1540312364808.png","_views_template":"0","_wpml_word_count":"{\"total\":0,\"to_translate\":{\"da\":14,\"nl\":14,\"en\":14,\"fi\":14,\"fr\":14,\"de\":14,\"pl\":14,\"es\":14,\"sv\":14}}","wpcf-gallerie":"http:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/Evergreen-School-3rd-Party-Report-30-percent-kWh-reduction_page6_image1_1540312371104.png","_wpcf-gallerie-sort-order":"","_wpml_media_duplicate":"","_wpml_media_featured":"","_top_nav_excluded":"","_cms_nav_minihome":"","_alp_processed":"","_last_translation_edit_mode":"","yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.9.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Lyeffion Elementary School Energienutzungstest mit ThermaCote Keramikbeschichtung | ThermaCote Europe<\/title>\n<link rel=\"canonical\" href=\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lyeffion Elementary School Energienutzungstest mit ThermaCote Keramikbeschichtung | ThermaCote Europe\" \/>\n<meta property=\"og:url\" content=\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/\" \/>\n<meta property=\"og:site_name\" content=\"ThermaCote Europe\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermaCote.Europe\/?ref=br_rs\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@thermacotefr\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/thermacote.eu\/#organization\",\"name\":\"ThermaCote Europe\",\"url\":\"https:\/\/thermacote.eu\/\",\"sameAs\":[\"https:\/\/www.facebook.com\/ThermaCote.Europe\/?ref=br_rs\",\"https:\/\/www.linkedin.com\/company\/thermacote-europe\/\",\"https:\/\/twitter.com\/thermacotefr\"],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/thermacote.eu\/#logo\",\"inLanguage\":\"de\",\"url\":\"https:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/logo-full.png\",\"width\":1535,\"height\":242,\"caption\":\"ThermaCote Europe\"},\"image\":{\"@id\":\"https:\/\/thermacote.eu\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/thermacote.eu\/#website\",\"url\":\"https:\/\/thermacote.eu\/\",\"name\":\"ThermaCote Europe\",\"description\":\"ThermaCote Europe\",\"publisher\":{\"@id\":\"https:\/\/thermacote.eu\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/thermacote.eu\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/#webpage\",\"url\":\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/\",\"name\":\"Lyeffion Elementary School Energienutzungstest mit ThermaCote Keramikbeschichtung | ThermaCote Europe\",\"isPartOf\":{\"@id\":\"https:\/\/thermacote.eu\/#website\"},\"datePublished\":\"2019-12-12T09:11:39+00:00\",\"dateModified\":\"2019-12-12T09:11:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/thermacote.eu\/de\/\",\"url\":\"https:\/\/thermacote.eu\/de\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/thermacote.eu\/de\/case-study\/\",\"url\":\"https:\/\/thermacote.eu\/de\/case-study\/\",\"name\":\"Case studies\"}},{\"@type\":\"ListItem\",\"position\":3,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/\",\"url\":\"https:\/\/thermacote.eu\/de\/case-study\/lyeffion-elementary-school-energienutzungstest-mit-thermacote-keramikbeschichtung\/\",\"name\":\"Lyeffion Elementary School Energienutzungstest mit ThermaCote Keramikbeschichtung\"}}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","toolset-meta":{"case-studies-custom-fields":{"main-image":{"type":"image","raw":"http:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/Evergreen-School-3rd-Party-Report-30-percent-kWh-reduction_page5_image1_1540312364808.png","attachment_id":3872},"gallerie":{"type":"image","raw":["http:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/Evergreen-School-3rd-Party-Report-30-percent-kWh-reduction_page6_image1_1540312371104.png","http:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/Evergreen-School-3rd-Party-Report-30-percent-kWh-reduction_page5_image1_1540312364808.png"],"repeatable":[{"raw":"http:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/Evergreen-School-3rd-Party-Report-30-percent-kWh-reduction_page6_image1_1540312371104.png","attachment_id":3863},{"raw":"http:\/\/thermacote.eu\/wp-content\/uploads\/2019\/11\/Evergreen-School-3rd-Party-Report-30-percent-kWh-reduction_page5_image1_1540312364808.png","attachment_id":3872}]},"description":{"type":"wysiwyg","raw":"Der Energieverbrauch zwischen zwei R\u00e4umen, Classroom #12 wurde ausgew\u00e4hlt, um mit dem Produkt beschichtet werden, mit dem angrenzenden Klassenzimmer #11 als Kontrollvergleich zugeordnet werden. Die Testr\u00e4ume sind von gleicher Gr\u00f6\u00dfe mit der exakt gleichen Menge an Au\u00dfenglas, die alle nach Westen ausgerichtet sind. Dar\u00fcber hinaus werden diese R\u00e4ume durch abgestimmte 2 1\/2-Ton Bard Wandhalterungen gek\u00fchlt. Diese Einheiten haben dieselbe Modellnummer und haben nahezu sequenzielle Seriennummern, die darauf hinweisen, dass sie innerhalb von Tagen oder Stunden voneinander hergestellt wurden.\n\nIn beiden Klassenzimmern wurden bei drei verschiedenen Gelegenheiten Messwerte aufgezeichnet. Stromverbrauch in der letzten Periode von ca. 22,5 Stunden ergaben eine Reduzierung der KWH-Nutzung um 40 %. Neueste Lesungen zeigen das ThermaCote Klassenzimmer bei 129 KWH und das unbeschichtete Klassenzimmer bei 202 KWH. Dies rechnet sich in einer 36,1%igen Reduzierung des Stromverbrauchs f\u00fcr die Klimaanlage im beschichteten Raum im Gegensatz zur Nutzung im Kontrollraum. Es ist zu beobachten, dass diese Anlage bereits eine helle Dachbeschichtung hatte. Die Anwendung dieses Materials auf dunkle D\u00e4cher oder die Unterseite der Dachterrasse mit dunklen Schindeln w\u00fcrde noch dramatischere Ergebnisse bewirken. Dar\u00fcber hinaus verf\u00fcgt ThermaCote \u00fcber eine .83 Sonnenreflektivit\u00e4t, wie sie vom Cool Roof Rating Counsel festgelegt wurde. Diese hohe Strahlungsreflexion kann zu einer Verringerung der Anzahl der Leuchtstoffr\u00f6hren f\u00fchren, die ben\u00f6tigt werden, um eine angemessene Menge an Licht an die Desktops zu liefern, was m\u00f6glicherweise die Einsparungen beim Beleuchtungsanteil der Stromrechnung erh\u00f6hen k\u00f6nnte."},"documentations":{"type":"file","raw":[],"repeatable":[]}}},"meta_box":[],"_links":{"self":[{"href":"https:\/\/thermacote.eu\/de\/wp-json\/wp\/v2\/case-study\/9076"}],"collection":[{"href":"https:\/\/thermacote.eu\/de\/wp-json\/wp\/v2\/case-study"}],"about":[{"href":"https:\/\/thermacote.eu\/de\/wp-json\/wp\/v2\/types\/case-study"}],"wp:attachment":[{"href":"https:\/\/thermacote.eu\/de\/wp-json\/wp\/v2\/media?parent=9076"}],"wp:term":[{"taxonomy":"application-type","embeddable":true,"href":"https:\/\/thermacote.eu\/de\/wp-json\/wp\/v2\/application-type?post=9076"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}